Tivoli Header
Resource Model Reference
The work item shortage is too high and the Windows NT registry needs to be
adjusted. This indication occurs when there is only a high work item
shortage. This can be remedied by adjusting the max work items in the
registry.
The indication has the following attributes:
- WorkItemShortages
- The number of times that work items cannot be allocated to service
incoming requests to the server
The indication is generated when the following thresholds are
exceeded:
Threshold
| Description
| Default
|
High Percent Bytes Per Second (HighPercentBytesSec)
|
To test for a high amount of bytes per second, a dynamic threshold value needs
to be created based on the current bandwidth of the network interface
card. Because there will be an internal dynamic calculation, the
threshold value is a percentile that indicates what percentage of the
bandwidth is considered too high. For example: 830 KBPS is
considered high for 10 MB ethernet networks. This value is about 8
percent.
| 9
|
High Percent Utilization (HighPercentUtilization)
|
This threshold determines at what point the network utilization of the
internal segment is too high.
| 40
|
High Work Item Shortages (HighWorkItemShortages)
|
This threshold must not be exceeded.
| 10
|
The following table shows the default settings for this indication:
Setting
| Default
|
Send indications to Tivoli Enterprise Console
| Yes
|
Send indications to Tivoli Business Systems Manager
| No
|
Occurrences
| 6
|
Holes
| 1
|
[ Top of Page | Previous Page | Next Page | Table of Contents | Index ]