Link-edit QMF with CICS command interface modules
DSQ1ELNK link-edits QMF with the CICS command interface modules, DFHEAI
and DFHEA10, located in the LOADLIB data set generated by CICS.
Important
To include CICS interface modules DFHEAI and DFHEAI0,
you must run this step each time you apply QMF service.
- Edit QMF720.QMFSAMPE(DSQ1ELNK).
- Verify that the installation parameters in the instream procedure
of the job, and the job steps, match your tailoring specifications.
//DSQ1ELNK PROC REG=4096K, Job Step Region
// QMFTPRE='QMF720 ', DSN Prefix for QMF product
// CLOAD='CICS.LOADLIB', Name of CICS LOADLIB
// OUTC='* Print SYSOUT class
- Submit QMF720.QMFSAMPE(DSQ1ELNK).
- Check for a return code of 0. If the return code is not 0, correct
the problem and rerun DSQ1ELNK.
[ Previous Page | Next Page | Contents | Index ]