Printing objects

The rules for printing QMF and database objects vary, depending on the type of object. Table 64 summarizes the requirements for each object.

Table 64. Summary of print requirements for QMF and database objects
Object type Nickname required GDDM gets control Where output is routed for OS/390 or VM Where output is routed for VSE
Chart Yes GDDM ICU always gets control when the PRINT command is issued. Output is controlled by GDDM. Destination associated with TONAME in the ADMMNICK specification.
Form Yes GDDM always gets control when the PRINT command is issued. Output is controlled by GDDM. Destination associated with TONAME in the ADMMNICK specification.
QBE query No Only if the nickname is supplied on the PRINT command or in profile. Output goes to the device associated with the GDDM nickname or the ddname DSQPRINT. Temporary storage or transient data queue. If a Nickname is supplied, output goes to the destination associated with TONAME in the ADMMNICK specification.
Procedure No Only if the nickname is supplied on the PRINT command or in profile. Output goes to the device associated with the GDDM nickname or the ddname DSQPRINT. Temporary storage or transient data queue. If a Nickname is supplied, output goes to the destination associated with TONAME in the ADMMNICK specification.
Profile No Only if the nickname is supplied on the PRINT command or in profile. Output goes to the device associated with the GDDM nickname or the ddname DSQPRINT. Temporary storage or transient data queue. If a nickname is supplied, output goes to the destination associated with TONAME in the ADMMNICK specification.
Prompted query Yes GDDM always gets control when the PRINT command is issued. Output is controlled by GDDM. Destination associated with TONAME in the ADMMNICK specification.
Report No Only if the nickname is supplied on PRINT command or in profile. Output goes to the device associated with the GDDM nickname or the ddname DSQPRINT. Temporary storage or transient data queue. If a nickname is supplied, output goes to the destination associated with TONAME in the ADMMNICK specification.
SQL query No Only if the nickname is supplied on the PRINT command or in profile. Output goes to the device associated with the GDDM nickname or the ddname DSQPRINT. Temporary storage or transient data queue. If a nickname is supplied, output goes to the destination associated with TONAME in the ADMMNICK specification.
Table No Only if the nickname is supplied on the PRINT command or in profile. Output goes to the device associated with the GDDM nickname or the ddname DSQPRINT. Temporary storage or transient data queue. If a nickname is supplied, output goes to the destination associated with TONAME in the ADMMNICK specification.
[ Previous Page | Next Page | Contents | Index ]