Administration Guide
To find out about GigaNet products, or to contact GigaNet
Service and Support, please use the following URL:
http://www.giganet.com/
The list of the hardware and software required to setup
this environment include the following products:
- GigaNet GNN1000 Network Interface Card
- GigaNet GNX5000 Switch
- GigaNet GNCxx11 Copper Interconnect Cables
- GigaNet cLAN Software, Version 2.0.
The steps required to ensure that GigaNet Interconnect can work with DB2
UDB are shown below. Each step is a summary of what is required at each
step: all of the details associated with each step are not presented
here. You should also use the referenced documentation at each step
which does provide detailed instructions and direction needed.
Each GigaNet GNN1000 is packaged with a GigaNet cLAN Software
CD-ROM. The CD-ROM contains all of the necessary software to set-up the
GigaNet Interconnect. In addition, the CD-ROM also contains the VI
Architecture SDK and Adobe Acrobat Reader. These two items are only
needed by those individuals that are developing VI-enabled
applications.
Summary of steps:
- Install Adapter Cards
- Install Switches and Cables
- Install Adapter Drivers
- Install cLAN Management Console
- Test the Interconnect
Here are the steps:
- Install the GigaNet GNN1000 Network Interface Card. Please refer to
the GigaNet GNN1000 User Guide for installation instructions.
- Install the GigaNet GNX5000 Switch and Cables. Please refer to the
GigaNet GNX5000 User Guide for installation instructions.
- Install the GigaNet GNN1000 Adapter Driver software on each node connected
to the GNX5000 Switch. Please refer to the GigaNet GNN1000 User
Guide for installation instructions. Here are additional details if you are
installing drivers provided by GigaNet:
- Remove any previous version of the GNN1000 Driver already
installed. Removal requires the node to be re-booted.
- Use Start>Setting>Control
Panel>Networks>Adapters>Add to install the
driver.
- Click Have Disk... and specify the Driver
directory on the CD-ROM. For example, if F: is your CD-ROM drive,
then you would use F:\Driver
- Select "GNN1000 NDIS Adapter" and then click OK.
- Configure Network protocols to complete the installation.
GigaNet Adapter Driver software is also available on GigaNet's web
site, http://www.giganet.com. Please
refer to the download and installation instructions found on the support page
of GigaNet's web site.
The installation of the GNN1000 Adapter Driver causes the node to
re-boot.
- The GigaNet cLAN Management Console (GMC) can be used to test the
integrity of the GigaNet Interconnect. The GigaNet cLAN Management
Console is comprised of two parts: the Console, and the Agent.
The Agent must be installed on all nodes in the cluster. The Console
can be installed on any network node that has access to the nodes in the
cluster. The most versatile and recommended installation is that which
has both the Console and the Agent installed on each node in the
cluster.
Install the GigaNet cLAN Management Console. Please refer to the
GigaNet GNN1000
User Guide for installation instructions and additional information about the cLAN
Management Console. Here are additional details on the installation
procedure:
- Insert the cLAN Software CD into the CD-ROM drive.
- Wait for the CD automatic installation menu to appear.
- Click on "Install cLAN Management Console."
- Repeat this installation procedure on each remaining node in the
cluster.
GigaNet cLAN Management Console software is also available on
GigaNet's web site,
http://www.giganet.com. Please refer to
the download and installation instructions found on the support page of
GigaNet's web site.
The installation of the cLAN Management Console may cause the node to
re-boot.
- Test that the GigaNet Hardware is working. This can be done by
doing the following:
- Open the GMC. (Programs>GigaNet>cLAN Management
Console)
- A dialog box is displayed showing all accessible machines in the
LAN. Press ESC.
- Select Console>Local from the menu bar.
- Confirm that all the members in the cluster are shown and that they are
all "Active".
- Select Utilities>VI Throughput from the menu bar.
This will run a throughput test to check that the data is actually going
through the hardware.
- Enter in uppercase letters the computer names of the two nodes you wish to
use in the test. Identify the local node as the source node.
- Click Start Measuring. You should see data being
transferred at a rate of at least 65 MB per second.
- Click Stop Measuring to stop the connection test.
- Repeat the test for the other nodes in the cluster by measuring throughput
between the local node (Source) and the other nodes (Sink).
If the connection test does not appear to be working, refer to the
troubleshooting sections of the GigaNet GNN1000 User Guide and the GigaNet GNX5000 User Guide.
See Install DB2 Universal Database Version 5.2 or Later (EEE) for information on how to install and implement DB2 UDB to
work with GigaNet Interconnect.
[ Top of Page | Previous Page | Next Page | Table of Contents | Index ]
[ DB2 List of Books |
Search the DB2 Books ]