Step 14--Bind communications package to DB2 UDB for OS/390

Skip this step if you are not using the DB2 UDB for OS/390 communications package.

DSQ1BICD binds the DB2 UDB for OS/390 communications package to QMF.

  1. Edit QMF720.SDSQSAPE(DSQ1BICD).
  2. Verify that the installation parameters in the instream procedure of the job match your tailoring specifications. If they do not, return to Step 2--Tailor the jobs and correct your installation parameters.
    //DSQ1BICD PROC RGN='2048K',      Job-step region size
    //    QMFTPRE='QMF720 ',          Prefix for QMF  target libraries
    //    DB2EXIT='DSN710.SDSNEXIT',  Exit DB2 UDB for OS/390  library name
    //    DB2LOAD='DSN710.SDSNLOAD'   DB2 UDB for OS/390 program
                                      library name
  3. Submit job QMF720.SDSQSAPE(DSQ1BICD).
  4. Check for a return code of 4 or less.

    Do not proceed if the return code is higher than four. Examine SYSTSPRT or SYSPRINT for error messages. Perform corrective actions and rerun the job.

[ Previous Page | Next Page | Contents | Index ]