Tivoli Header
User's Guide
To enable monitoring of Tivoli Monitoring events on a Tivoli Enterprise
Console server, you need to import the Tivoli Monitoring BAROC files into the
rule base used by the Tivoli Enterprise Console server.
To accomplish this you need to either follow the procedure detailed below,
or run the Tivoli-provided script that carries out the procedure steps for
you:
- Running the script
- A script has been provided to enable you to update the rule base in a
semi-automatic way. The script is named
dmae_tec_inst.sh, and is stored in the
$BINDIR/TMNT_TEC directory.
The script must be run on the Tivoli Enterprise Console
server. It takes as an argument the name of the rule_base of
the Tivoli Enterprise Console server where the BAROC rules are to be
stored. You can also optionally specify the parameter
-restartsvr to restart the server at the end of the
script.
- Following the procedure
- If you do not want to run the script, you can follow the individual steps
that the script performs, which are detailed in the procedure set out
below. For full information about performing each step of the
procedure, refer to the Tivoli Enterprise Console Rule Builder's
Guide.
Perform the following steps:
- Select an existing rule base or create a new rule base to contain the
Tivoli Monitoring BAROC files.
- Import the required BAROC files from the $BINDIR/TMNT_TEC
directory into the rule base.
It is important that you import the files in the following order:
- Import the Tmw2k.baroc file. For more information
about it, see the Tivoli Enterprise Console Rule Builder's
Guide.
- Import the BAROC files for all the resource models whose events you want
to send to Tivoli Enterprise Console server.
- Import the hb_events.baroc file to enable heartbeat
messages.
- Import the required heartbeat rules file from the
$BINDIR/TMNT_TEC directory into the rule base to enable the support
of heartbeat messages. The file is called
hb_events.rls.
- Import the required clearing event rules file from the
$BINDIR/TMNT_TEC directory into the rule base to enable clearing
events to close the error events to which they relate. The file is
called dmae_events.rls. If you omit this step, the
Tivoli Enterprise Console server will not close related error events, and the
clearing event will be displayed.
- Compile and load the rule base.
- Stop and restart the Tivoli Enterprise Console server.
The Tivoli Enterprise Console server is now ready to receive Tivoli
Monitoring events from the monitoring sources whose corresponding BAROC files
you have imported into the active rule base.
To see the events sent by Tivoli Monitoring, from the Tivoli Enterprise
Console main dialog, click the All icon. See the Tivoli Enterprise Console: User's Guide for
more details.
- Note:
- The BAROC available with Tivoli Monitoring 5.1 can also be used with
Tivoli Distributed Monitoring (Advanced Edition) 4.1 or with Tivoli
Distributed Monitoring for Windows 3.7 Patch 3.
[ Top of Page | Previous Page | Next Page | Table of Contents | Index ]