Rebuilding the lock structure
When a coupling facility lock structure fails, the SMSVSAM servers attempt to rebuild their locks in the lock structure from their own locally-held copies of the locks. If this is successful, the failure is transparent to CICS®.
About this task
If the rebuild fails, all SMSVSAM servers abend and restart, but they are not available for service until they can successfully connect to a new coupling facility lock structure. Thus a lock structure failure is initially detected by CICS as an SMSVSAM server failure, and CICS issues message DFHFC0153.
When the SMSVSAM servers abend because of this failure, the sharing control
data set is updated to reflect the lost locks condition. The sharing control
data set records:
- The data sets whose locks have been lost.