Checking coupling facility structure and couple data set status
To display the MVS logger couple data set status, issue the following MVS
command:
D XCF,CPL,TYPE=LOGR
A normal response looks like this:
D XCF,CPL,TYPE=LOGR
IXC358I 14.47.51 DISPLAY XCF 391
LOGR COUPLE DATA SETS
PRIMARY DSN: SYS1.SYSPLEX2.SEQ26.PLOGR
VOLSER: P2SS05 DEVN: 230D
FORMAT TOD MAXSYSTEM
12/20/95 09:25:48 8
ALTERNATE DSN: SYS1.SYSPLEX2.SEQ26.ALOGR
VOLSER: P2SS06 DEVN: 2C10
FORMAT TOD MAXSYSTEM
12/20/95 09:27:45 8
LOGR IN USE BY ALL SYSTEMS
If the response shows that LOGR
is not in use by all systems, there may be a problem to investigate. Look
for IXCxxx messages which might indicate the cause of the problem and issue
the following command to attempt reconnection to the couple data set: SETXCF CPL,TYPE=(LOGR),PCOUPLE=(couple_dataset_name)
To display all structures with Failed_persistent connections, issue the
following MVS command:
D XCF,STR,STRNM=*,STATUS=FPCONN
The
MVS logger should resolve any failed connections.