Defining component tracing when the CICS system is running

You can use the CETR transaction to define component tracing dynamically on the running CICS® system.

Figure 1 shows you what the CETR Component Trace Options screen looks like. To make changes, overtype the settings shown on the screen, and then press ENTER.
Figure 1. CETR screen for specifying component trace options
 CETR           Component Trace Options
 Overtype where required and press ENTER.                     PAGE 1 OF 3
 Component Standard                           Special
 --------  -------------------------------    ---------------------------
   AP      1-2                                1-2
   BA      1                                  1-2
   BM      1                                  1
   BR      1                                  1-2
   CP      1                                  1-2
   DC      1                                  1
   DD      1                                  1-2
   DH      ALL                                1-2
   DM      1                                  1-2
   DP      1                                  1-2
   DS      1                                  1-2
   DU      1                                  1-2
   EC      1                                  1-2
   EI      1-2                                1-2
   EJ      1                                  1-2
   EM      1                                  1-2
   EP      1                                  1-2
   FC      1                                  1-2
   GC      1                                  1-2
   IC      1                                  1-2
   IS      1                                  1-2
 PF:  1=Help   3=Quit   7=Back  8=Forward  9=Messages   ENTER=Change

The trace levels for a specific CICS component are represented by two values. One value shows the active level of tracing for standard tracing; the other shows possible levels for special tracing. In CETR, you can set the active level of tracing for standard or special tracing for an individual component or for a group of components.

In this example, all components except AP, DH and EI have level-1 tracing enabled during standard tracing. AP and EI have both level-1 and level-2 tracing enabled, which will provide more detailed information than level-1 tracing alone. The DH component has a standard trace setting of ALL, which will provide the maximum amount of trace information possible.

For special tracing, all components except BM and DC can have level-1 and level-2 tracing enabled.

Level-1 trace points are designed to give you enough diagnostic information to fix errors caused by user applications or user actions, while level-2 trace points provide information that is likely to be more useful for fixing errors within CICS code. Generally, you will not want to use level-2 trace points yourself, unless requested to do so by IBM® support staff after you have referred a problem to them.



dfhs1c00237.html | Timestamp icon Last updated: Monday, 5 June 2017