EYUXS1018E E   ESSS disconnect failed, RESP nnn.

Explanation

The CICSPlex SM task recovery TRUE, EYU9XSTR, executing in a local MAS, encountered an invalid return code when requesting that the MAS be disconnected from the ESSS where:
nnn
Is the invalid return code

System action

Processing continues.
Note: This message is preceded by message EYUXS1017E.

User response

Collect as much of the following as possible and contact your IBM Support Center:
  • The complete job output.
  • the unformatted SVC dumps for any abends that may have occurred during the execution of the CMAS or MAS.
  • The unformatted AUXTRACE data sets (if the system is a MAS and AUXTRACE was not active in that system, collect the AUXTRACE data sets from the CMAS to which the MAS was connected).
Then restart the local MAS.

Module

EYU9XSTR

Destination

Console and SYSPRINT



EYUXS1018E.html | Timestamp icon Last updated: Sunday, 4 June 2017