EYUXS1012S S applid Interval Timing unable to attach the external security manager interface
Explanation
During initialization, the Interval Timing subcomponent attempted to use an MVS ATTACH command to start the external security manager task and the ATTACH failed, where applid is the z/OS Communications Server application ID of the CMAS.
System action
Interval Timing initialization terminates. CMAS initialization terminates.
User response
Check the system log for MVS Contents Supervisor messages, which begin with the prefix CSVnnn; these messages should explain the cause of the problem. If the cause of the problem is not apparent, collect the MVS system log and the CMAS job log and contact your IBM support center.
Module
EYU9XSTC
Destination
Console and SYSPRINT