EYUXL0105E E    date time applid ESSS connection failed.

Explanation

An attempt to establish a connection between the Kernel Linkage component and the Environment Services System Services (ESSS) has failed during initialization of an address space in the CICSPlex® SM environment.

System action

The impact on system processing depends on what type of address space was being initialized:

CMAS

The CMAS is terminated. CICSPlex SM takes an SVC dump with a dump code of EYUXL001.

MAS

The MAS is terminated. CICSPlex SM takes a transaction dump with a dump code of EYUI and returns control to CICS.

User response

The trace record indicates the reason for the ESSS connection failure. Depending upon what type of address space was initializing when the failure occurred, take one of the following actions:

CMAS

Make sure the JCL specifies the proper PLTPI program to identify the CMAS to the ESSS .

MAS

If the JCL specifies both a CICSplex and a CMAS , make sure the named CMAS is active.

If the JCL specifies only a CICSplex , make sure the CICSplex exists in at least one CMAS attached to the ESSS .

Module

EYU9XLEV

XMEOUT parameters/Message inserts

  1. date
  2. time
  3. applid

Destination

Console and COLG



EYUXL0105IE.html | Timestamp icon Last updated: Sunday, 4 June 2017