EYUXE0027W W Lock recovery failed - reason
Explanation
CICSPlex® SM uses its own logical lock scheme to serialize access to its shared resources. During CICSPlex SM address space (CMAS) or managed application system (MAS) termination, the MVS™ end-of-task routine provided by CICSPlex SM invokes a lock recovery PC routine to:
- Release control of any held locks
- Remove the CMAS or MAS from any queues on which it is waiting for control of locks.
- Insufficient storage for work area There was insufficient storage for a local work area required by the PC routine.
- Parameter list not addressable The parameter list passed as input to the PC routine was in storage that could not be addressed.
- Invalid parameter(s) One or more invalid parameters were found in the parameter list passed as input to the PC routine.
- Abnormal termination An abnormal termination was intercepted by the PC routine.
System action
The impact on system processing depends on the reason for the failure:
- The PC routine is unable to fulfill any of its responsibilities. This may result in errors in associated address spaces (that is, MASs associated with a CMAS or the CMAS associated with a MAS). It may also make it impossible to restart the terminating address space without first terminating all associated address spaces.
- The PC routine is unable to fulfill any of its responsibilities. This may result in errors in associated address spaces (that is, MASs associated with a CMAS or the CMAS associated with a MAS). It may also make it impossible to restart the terminating address space without first terminating all associated address spaces.
- The PC routine is unable to fulfill any of its responsibilities. This may result in errors in associated address spaces (that is, MASs associated with a CMAS or the CMAS associated with a MAS). It may also make it impossible to restart the terminating address space without first terminating all associated address spaces.
- The PC routine may have managed to partially fulfill its responsibilities before encountering the abnormal termination. Therefore, the result of the error cannot be predicted. Before returning control to the end-of-task exit, an attempt is made to obtain an SVC dump and a software error recording request is made to the MVS LOGREC facility.
User response
The appropriate response depends on the reason for the failure:
- Terminate all address spaces associated with the terminating address space. Then, restart all the address spaces. If the problem persists, contact your IBM® Support Center.
- Terminate all address spaces associated with the terminating address space. Then, restart all the address spaces. If the problem persists, contact your IBM Support Center.
- Terminate all address spaces associated with the terminating address space. Then, restart all the address spaces. If the problem persists, contact your IBM Support Center.
- Collect the following information and contact your IBM Support Center:
- The SVC dump, if one was obtained
- The job log, and
- The record written to the SYS1.LOGREC data set
Module
EYU9XEET
Destination
Console and SYSPRINT