EYUXE0025E E   ESSS and PC Routines Mismatch Encountered.

Explanation

During CMAS initialization, the Environment Services System Services (ESSS) IDENTIFY function determined that the generation dates of the ESSS address space code and the program call (PC) routines it uses were not the same.

System action

A dump is taken of the ESSS address space. The title of the dump is EYU9X530.CREATE.FAIL.DUMP. The creating CMAS issues this message and then terminates.

User response

Verify the following:
  • You have the latest versions of modules EYU9X530 and EYUTXEPC.
  • The library containing module EYU9X530 resides in the linklist.
Issue the MVS command F LLA,REFRESH to refresh the LNKLST LOOKASIDE address space (LLA). Then try to restart a CMAS. If this problem reoccurs, you must reIPL the system.

Module

EYU9XECS

Destination

Console and SYSPRINT