EYUXC0023S S    date time applid Maximum data cache limit has been reached for compid cache.

Explanation

Data Cache Manager was unable to extend an existing cache because it would require creation of another data cache area and the cache is already at its CICSPlex® SM defined maximum (CMAS only), where:

compid

is the abbreviation for the component whose cache is to be extended (for example, DAT for Data Repository ).

System action

Message EYUXC0024S is issued, SDUMP is taken and the CMAS is terminated. If CMAS initialization completed before the failure, an attempt is made to ARMRESTART the CMAS .

User response

Capture the CMAS job output and the SDUMP created in response to this error, and contact your IBM® Support Center .

Module

EYU0XCCL

XMEOUT parameters/Message inserts

  1. date
  2. time
  3. applid
  4. compid

Destination

Console and COLG



EYUXC0023AS.html | Timestamp icon Last updated: Sunday, 4 June 2017