EYUNX0009E E    LINK failed: RESP=respcode RESP2=resp2code

Explanation

An EXEC CICS LINK command was issued to begin MAS startup, and it returned an abnormal response. The respcode and resp2code values are as returned by CICS.

System action

A system dump is taken with a dump code of EYUN and control returns to CICS. The CICS® system continues to initialize, but it is not known to CICSPlex® SM.

User response

Make sure the load module for this program can be located for this CICS system. The program is named in preceding message EYUNX0008E. Follow the instructions associated with the RESP= and RESP2= values for this message for the EXEC CICS LINK command. If the problem persists, collect the dump and contact your IBM® Support Center.

Module

EYU9NXLM

Destination

Console and SYSPRINT



EYUNX0009E.html | Timestamp icon Last updated: Sunday, 4 June 2017