EYUNL0143W W date time applid MTRAN monitoring data incomplete - CICS Monitor data {missing. | truncated.}
Explanation
Some or all MTRAN monitoring data is unavailable because CICSPlex SM was not able to process CICS monitor data at exit point XMNOUT, where:
- reason
-
Identifies the reason why CICS monitor data could not be processed:
- missing
-
The work area for dictionary data was too small. All performance data will be discarded.
- truncated
-
The buffers used to pass performance data to the CICSPlex SM monitor component were too small. Performance records will be truncated.
System action
CICSPlex SM monitoring of MTRAN resources continues but some or all performance data provided by the CICS monitor domain will be missing. Data provided by CICS statistics domain will be collected and reported at monitor sample intervals.
User response
Collect AUXTRACE records and MAS and CMAS job logs and contact your IBM Support Center.
Module
XMEOUT parameters/Message inserts
- date
- time
- applid
- Value chosen from the following options:
1=missing., 2=truncated.
Destination
Console and COLG