DFHZC6904 W date time applid Autoinstall for {netname | consolename} id failed. CATA task abended (abend abend).
Explanation
Transaction CATA was autoinstalling a terminal or console, id, when the task abended with abend abend. If the resource being autoinstalled was a terminal, then the issuing module was DFHZATA. Otherwise, the issuing module was DFHZATA2 if the resource was a console. The id can be either a netname or a consolename.
System action
CICS continues but the resource is not installed.
User response
Retry the logon attempt. If the abend indicates a TIMEOUT and this occurs frequently, increase the CATA DTIMOUT value. If you do not want the CATA transaction to time out, remove the DTIMOUT parameter from the CATA DEFINE TRANSACTION command. However, if you do this, and if the system is short on storage, a large number of CATA transactions running at the some time with no other transactions present could cause a deadlock.
Module
XMEOUT parameters/Message inserts
- date
- time
- applid
- Value chosen from the following options:
1=netname, 2=consolename - id
- abend
Destination
CADL