DFHZC3433 E    date time applid termid tranid FMH7 was received on ISC session. Sense code is : xxxxxxxx { Error log data is : | No error log data received. | No error log data available. } xxxxxxxx sense ((instance) Module name: {DFHZRVX | DFHZRAC | DFHZRAC | DFHZERH})

Explanation

The transaction is communicating with a logical unit (LU) type LU6.1 or LU6.2.

The logical unit sent an FMH7 which may carry error log data. If error log data is included, then the text is inserted in this message. This imbed is inserted in DFHZC xxxx messages with sense inserts. For the meaning of sense , see message DFHZC2400.

System action

The action taken depends upon the sense code.

User response

If the receiving transaction is designed to handle this situation, no action is necessary. However, if this is not the case, use the sense code and any error log data to determine why the connected logical unit sent the FMH7.

If the connected LU is another CICS system, the error log data is a CICS message.

If the connected LU is not a CICS system, see that product's documentation for details of error log data. Some products permit the user to define the contents of error log data.

Module

DFHZRVX, DFHZRAC, DFHZERH

XMEOUT parameters/Message inserts

  1. date
  2. time
  3. applid
  4. termid
  5. tranid
  6. xxxxxxxx
  7. Value chosen from the following options:
  8. xxxxxxxx
  9. sense
  10. instance
  11. Value chosen from the following options:

Destination

CSNE