DFHZC2402 I date time applid termid tranid netname VTAM has returned error on synchronous receive. sense ((instance) Module name: {DFHZRAS})
Explanation
VTAM has indicated that a synchronous receive issued by DFHZRAS during receive-any slow-down processing did not complete successfully. This indicates a serious mismatch between CICS's view of the state of the session and that of VTAM. This imbed is inserted in DFHZC xxxx messages with sense inserts. For the meaning of sense , see message DFHZC2400.
System action
The request is ignored. CICS prints the associated session TCTTE on the CSNE transient data destination. The RPL returned by VTAM is included in exception trace entry AP FCA2.
User response
Determine from the RPL in the exception trace why VTAM raised the error.
Module
DFHZRAS
XMEOUT parameters/Message inserts
- date
- time
- applid
- termid
- tranid
- netname
- sense
- instance
- Value chosen from the following options:
1=DFHZRAS
Destination
CSNE