DFHZC0157 date time applid sysid VTAM APPC session termid could not be recovered following a persistent sessions restart. The session will be unbound.sense ((instance) Module name: {DFHZXPS})
Explanation
CICS was unable to restore the APPC persisting session for sysid termid following a persistent sessions restart. There are three possible reasons for this:
-
The BIND processing was incomplete when CICS failed.
-
Resynchronization was in progress for the session when CICS failed.
-
The recovery data returned by VTAM for the session was capable of more than one interpretation.
The TCTTE and TIOA are output for information only.
System action
The session is unbound and rebound.
User response
None.
Module
DFHZXPS
XMEOUT parameters/Message inserts
- date
- time
- applid
- sysid
- termid
- sense
- instance
- Value chosen from the following options:
1=DFHZXPS
Destination
CSNE