DFHXS0202 date time applid An attempt to track external security initialization has failed, tracking data could not be sent.
Explanation
An external security initialization was performed on an active CICS system (via CEMT PERFORM SECURITY, or EXEC CICS SECURITY REBUILD).
It has not been tracked to an alternate system because the tracking data could not be sent.
System action
CICS provides a system dump of the active, and continues tracking security initializations.
Message DFHME0116, which contains the symptom string for this problem, is produced.
User response
The security characteristics of the alternate will no longer match those of the active. Either shut down the alternate, perform a security rebuild at takeover, or accept the difference.
Module
DFHXSWM
XMEOUT parameters/Message inserts
- date
- time
- applid
Destination
CSCS