DFHSZ4014 E date time applid FEPI storage FREEMAIN failed in subpool DA|NB|RP, reason X'rr' response X'ee'.
Explanation
The Front End Programming Interface (FEPI) issued a FREEMAIN storage request in an SZSPxxxx storage subpool. The request failed.
The values of X'rr', the reason for failure, are:
- Reason
- Meaning
- X'02'
-
Invalid subpool token given.
- X'03'
-
The address of the element to be freed is invalid.
- X'06'
-
Invalid length of element specified.
- X'07'
-
Length of element not specified.
- X'08'
-
Access was denied to the storage subpool.
- X'10'
-
The specified storage subpool was empty.
- X'12'
-
An abnormal end occurred in the storage manager.
- X'13'
-
A loop was detected in the storage manager.
The values of X'ee', the response to the failed request, are:
- Response
- Meaning
- X'01'
-
Request completed successfully.
- X'02'
-
Exception response generated.
- X'03'
-
Disaster response generated.
- X'04'
-
Invalid response generated.
- X'05'
-
A kernel error was detected.
- X'06'
-
The request was purged.
All of these responses indicate that a system error occurred.
System action
The request is rejected, and a retry is not attempted (perhaps leaving storage that is never subsequently accessible). An exception trace entry is generated.
User response
If you need further assistance from IBM to resolve this problem, see IBM problem support for guidance on how to proceed.
Module
XMEOUT parameters/Message inserts
- date
- time
- applid
- X'rr'
- X'ee'
Destination
CSZL and Console