DFHST0001    applid An abend (code aaa/bbbb) has occurred at offset X'offset' in module modname.

Explanation

An abnormal end (abend) or program check has occurred in module modname. This implies that there may be an error in CICS code.

Alternatively, unexpected data has been input, or storage has been overwritten.

Note:

There is NO applid for DFHSTUP modules.

The code aaa/bbbb is a 3-digit hexadecimal MVS code (if applicable), followed by a 4-digit alphanumeric CICS code. The MVS code is a system completion code (for example, 0C1 or D37). If an MVS code is not applicable, this field is filled with three hyphens. The CICS code is an abend code or a number referring to a CICS message (for example, AKEA is a CICS abend code; 1310 refers to message DFHTS1310).

System action

An exception entry is made in the trace table.

For modules DFHSTST and DFHSTTI, a dump is taken and the collection interval is set to 24 hours. Message DFHST0101 is also issued.

For module DFHSTDM, the action depends on the initialization error action value which is used by the domain (DM) manager. The usual action is to terminate CICS with a dump.

For module DFHSTUE, processing continues.

For modules DFHSTWR, DFHSTRD, and DFHSTUx (modules within DFHSTUP), the job step is terminated with a dump.

For ALL modules, a system dump is taken, unless you have specifically suppressed dumps in the dump table.

Message DFHME0116, which contains the symptom string for this problem, is produced.

User response

If CICS is still running, it is necessary to decide whether to terminate CICS.

Look up the MVS code, if there is one, in the z/OS MVS System Codes manual. Then look up the CICS alphanumeric code in this manual. This tells you, for example, whether the error was a program check, an abend, a runaway or a recovery percolation, and may give you some guidance concerning user response.

If module modname is not crucial to the running of your CICS system, you may decide to continue to run and bring CICS down at a convenient time to resolve the problem.

If you cannot run without the full use of module modname, you should bring CICS down in a controlled shutdown.

If you need further assistance from IBM to resolve this problem, see IBM problem support for guidance on how to proceed.

Module

DFHSTST, DFHSTDM, DFHSTTI, DFHSTUE, DFHSTUx (Modules within DFHSTUP), DFHSTWR, DFHSTRD

XMEOUT parameters/Message inserts

  1. applid
  2. aaa/bbbb
  3. X'offset'
  4. modname

Destination

Console



DFHST0001.html | Timestamp icon Last updated: Sunday, 4 June 2017