DFHRS2151 date time applid Invalid data has been received during the resynchronization sequence on session sessid from remote system sysid, netname netname, protocol protocol.
Explanation
The local system was attempting to receive data as part of a resynchronization sequence but the conversation was in the wrong state or an error FMH was received.
The remote system was attempting to initialize the connection for synclevel 2 work or to resynchronize distributed resources following an earlier failure of a protected conversation during sync point processing.
The failure implies one of the following:
-
An error was detected by the remote system and it sent an error indication in an FMH7.
-
An error occurred in the remote system
-
A CICS logic error has occurred.
System action
A system dump is taken unless you have specifically suppressed dumps in the dump table.
Message DFHME0116, which contains the symptom string for this problem, is produced.
If resynchronization was being attempted, it has failed and will be retried at the next opportunity.
User response
The sequence of resynchronization can be retried by issuing CEMT SET CONN(sysid) RESYNC.
Investigate the cause of the error using the system dump and any diagnostic information already issued by CICS, the access methods or the operating system.
Format the system dump to show the control blocks belonging to the trace domain. (For guidance on how to do this, see the Troubleshooting and support section.)
The trace entries show the state of the conversation with the remote system and the arrival of any error FMH indicating an error detected in the remote system. If necessary, obtain further diagnostic material from the remote system.
Module
XMEOUT parameters/Message inserts
- date
- time
- applid
- sessid
- sysid
- netname
- protocol
Destination
CSMT and Console