DFHRS2150    date time applid Invalid data has been received during the resynchronization sequence on session sessid from remote system sysid, netname netname, protocol protocol.

Explanation

The local system has received data which it attempted to parse as one of the following types of SNA GDS data:

  • Exchange log names
  • Do_know
  • System_restart

The data could not be recognized.

The remote system was attempting to initialize the connection for synclevel 2 work, or to resynchronize distributed resources following an earlier failure of a protected conversation during sync point processing.

This failure implies one of the following:

  • An error was detected by the remote system and it sent an error indication in an FMH7.

  • An error has occurred in the remote system.

  • A CICS logic error has occurred.

System action

A system dump is taken unless you have specifically suppressed dumps in the dump table.

Message DFHME0116, which contains the symptom string for this problem, is produced.

If resynchronization was being attempted, it has failed and is retried at the next opportunity.

For APPC protocol connections (but not IRC protocol), the failure prevents the completion of the exchange log names protocol and this prevents any synclevel 2 attaches between the local system and the remote system.

User response

For APPC protocol connections, issue CEMT INQUIRE CONN(sysid), and examine the XOK field. If exchange log names has not been done but there has been previous contact between the systems, the error can be overridden by resetting the state of the connection. To do this, issue the CEMT SET CONN(sysid) NORECOVDATA command for the failing connection. It may be necessary to issue this command (or its equivalent) on both sides of the connection.

Note:

If this command is issued, CICS unilaterally commits any resources which may be waiting for APPC resynchronization. In addition, CICS does not carry out any APPC resynchronization activity with the remote system.

Investigate the cause of the error using the system dump and any diagnostic information provided by CICS, the access methods, or the operating system.

Format the system dump to show the control blocks belonging to the trace domain. (For guidance on this, see the Troubleshooting and support section.)

An trace entry contains the received data. Check the format of this data. The correct format of the SNA defined field can be found in the z/OS Communications Server: SNA Data Areas Volume 2 manual.

A possible cause is that the remote system did not send a valid GDS variable. In this case, it may be necessary to obtain further diagnostic material from the remote system.

Module

DFHCRRSY

XMEOUT parameters/Message inserts

  1. date
  2. time
  3. applid
  4. sessid
  5. sysid
  6. netname
  7. protocol

Destination

CSMT and Console



DFHRS2150.html | Timestamp icon Last updated: Sunday, 4 June 2017