DFHRS2134 date time applid An error has occurred while sending an exchange log names request on session sessid to remote system sysid, netname netname, protocol protocol.
Explanation
An error has occurred during the transmission of an exchange log names request to a remote system. CICS was attempting to establish the connection on first contact with the partner, or to resynchronize distributed resources following an earlier failure of a protected conversation during sync point processing.
This message implies a failure of the session used to carry the transmission.
System action
A system dump is taken unless you have specifically suppressed dumps in the dump table.
Message DFHME0116, which contains the symptom string for this problem, is produced.
In many cases CICS continues to operate normally, and the resynchronization or connection establishment is retried in an attempt to overcome the session failure. However for APPC protocol, a repeated failure may have resulted in exchange log names flows being unsuccessful preventing any synclevel 2 attaches between the local system and the remote system.
For IRC protocol, resynchronization has failed but the connection continues to operate normally.
User response
Issue CEMT INQUIRE CONN(sysid) and look at the XOK field. If exchange log names has not been done, the exchange log names process can be retried by issuing the CEMT SET CONN(sysid) RESYNC command.
Investigate the cause of the error using the system dump and any previously output diagnostic information provided by CICS, the access methods, or the operating system, and examine the log of the remote system. If a protocol violation was detected, the remote system may have generated diagnostic information itself.
Format the system dump to show the control blocks belonging to the trace domain. (For guidance on how to do this, see the Troubleshooting and support section.)
Determine from the message which session was being used for this exchange log names conversation.
If the internal trace table is available, use it to track the commands issued against that session and check that the state transitions of the User state machine are correct. If any of the state transitions are not valid, it is possible that there has been a CICS logic error.
Module
XMEOUT parameters/Message inserts
- date
- time
- applid
- sessid
- sysid
- netname
- protocol
Destination
CSMT and Console