DFHRP1991    date time applid tranid The CICS ONC RPC connection manager has detected an invalid server data length returned by the Getlengths function of converter converter_program_name. Program: X'prognum' Version: X'versnum' Procedure: X'procnum' Protocol: protocol. Host IP address: hostaddr.

Explanation

The communication area length calculated from the glength_server_data_format, glength_server_input_data_len, and glength_server_output_data_len parameters exceeds 32 767.

System action

The Getlengths parameter area is traced. The 4-tuple is not registered.

User response

Use the trace information to correct the converter.

Module

DFHRPC0E

XMEOUT parameters/Message inserts

  1. date
  2. time
  3. applid
  4. tranid
  5. converter_program_name
  6. X'prognum'
  7. X'versnum'
  8. X'procnum'
  9. protocol
  10. hostaddr