DFHRP1951 date time applid tranid The CICS ONC RPC connection manager could not load the requested XDR program xdrname. EIBRESP: eibresp EIBRESP2: eibresp2 Program: X'prognum' Version: X'versnum' Procedure: X'procnum' Protocol: protocol. Host IP address: hostaddr.
Explanation
The connection manager used EXEC CICS LOAD for the CICS program xdrname, which has been requested as the XDR routine for the 4-tuple being processed, but received an error response.
System action
The 4-tuple is not registered.
User response
The problem is probably due to an error in defining the requested program xdrname to CICS, or to wrongly defining an XDR routine name for the 4-tuple. Use the values provided in eibresp and eibresp2 to identify the reason for the error in the LOAD, and use the CICS CEDA transaction or the connection manager to rectify the problem.
Module
DFHRPC0E
XMEOUT parameters/Message inserts
- date
- time
- applid
- tranid
- xdrname
- eibresp
- eibresp2
- X'prognum'
- X'versnum'
- X'procnum'
- protocol
- hostaddr
Destination
CRPO