DFHRP1901    date time applid tranid The CICS ONC RPC connection manager could not find the task-related user exit, program DFHRPTRU.

Explanation

The connection manager cannot find the task-related user exit, DFHRPTRU, for one of the following reasons:

  • DFHRPTRU has not been defined to CICS

  • DFHRPTRU is not in the CICS load library

  • DFHRPTRU has been disabled

System action

A system dump is taken. CICS ONC RPC remains disabled. Message DFHME0116, which contains the symptom string for this problem, is produced.

User response

Ensure that all the CEDA groups for CICS ONC RPC have been installed correctly, then try the enable request again.

Module

DFHRPC0B

XMEOUT parameters/Message inserts

  1. date
  2. time
  3. applid
  4. tranid

Destination

CRPO



DFHRP1901.html | Timestamp icon Last updated: Sunday, 4 June 2017