DFHRP1768    date time applid tranid The CICS ONC RPC connection manager detected a logic error while accessing the CICS ONC RPC data set, CICS file filename.

Explanation

The connection manager could not access the CICS ONC RPC data set. This is a logic error since the connection manager has received an unexpected response from CICS following an EXEC CICS STARTBR, EXEC CICS READNEXT or EXEC CICS ENDBR command.

The error occurred while processing a request to display 4-tuple definitions from the data set.

Without access to the data set, the connection manager cannot process requests to display information from it.

System action

A system dump is taken. The connection manager panel is redisplayed. Message DFHME0116, which contains the symptom string for this problem, is produced.

User response

You need further assistance from IBM to resolve this problem. See External Interfaces Guide and IBM problem support for guidance on how to proceed. Report the details of the symptom string given in message DFHME0116. It will aid problem determination.

Module

DFHRPC0A

XMEOUT parameters/Message inserts

  1. date
  2. time
  3. applid
  4. tranid
  5. filename

Destination

CRPO