DFHRP1551 date time applid tranid The CICS ONC RPC connection manager could not enable CICS ONC RPC because of a CICS short on storage condition.
Explanation
The connection manager has made a request for storage during enable processing, but has received a reply indicating that CICS is short on storage.
System action
A system dump is taken. The enable attempt is abandoned. Message DFHME0116, which contains the symptom string for this problem, is produced.
User response
See the associated diagnostics issued by CICS for problem determination. You need further assistance from IBM to resolve this problem. See External Interfaces Guide and IBM problem support for guidance on how to proceed. Report the details of the symptom string given in message DFHME0116. It will aid problem determination.
Module
DFHRPC4C
XMEOUT parameters/Message inserts
- date
- time
- applid
- tranid
Destination
CRPO