DFHRP1541    date time applid tranid The CICS ONC RPC connection manager detected a logic error.

Explanation

The connection manager received an unexpected response from CICS following an EXEC CICS command.

System action

A system dump is taken. The enable attempt is abandoned. Message DFHME0116, which contains the symptom string for this problem, is produced.

User response

You need further assistance from IBM to resolve this problem. See External Interfaces Guide and IBM problem support for guidance on how to proceed. Report the details of the symptom string given in message DFHME0116. It will aid problem determination.

Module

DFHRPC4C

XMEOUT parameters/Message inserts

  1. date
  2. time
  3. applid
  4. tranid

Destination

CRPO



DFHRP1541.html | Timestamp icon Last updated: Sunday, 4 June 2017