DFHRP1515    date time applid tranid The CICS ONC RPC connection manager detected an error while accessing the CICS ONC RPC data set, CICS file filename. EIBRESP: eibresp.

Explanation

The connection manager could not access the CICS ONC RPC data set, CICS file filename. An EXEC CICS READ was issued, but received the response eibresp. The error can occur for one of the following reasons:

  • The file is defined as remote, and there is an error on the connection to the owning system.

  • VSAM has returned an unexpected response to CICS.

  • An I/O error occurred on the READ.

System action

A system dump is taken. The requested operation is not performed. Message DFHME0116, which contains the symptom string for this problem, is produced.

User response

Use Appendix A of the Reference: application development manual to find out what the EIBRESP value means, and take appropriate action.

Module

DFHRPC09

XMEOUT parameters/Message inserts

  1. date
  2. time
  3. applid
  4. tranid
  5. filename
  6. eibresp

Destination

CRPO