DFHPG0208    date time applid terminal userid tranid Autoinstall for program progname failed.

Explanation

An attempt has been made to autoinstall a program during link, XCTL, load, or exit processing but the install of the definition failed. Either the AMODE/RMODE combination is invalid or the load attribute and type combination is invalid. Where:

  • terminal is the netname or termid of the terminal associated with the transaction issuing the message. If there is no terminal associated with the transaction, the terminal name is suppressed.

  • userid is the user identifier of the user associated with the transaction issuing the message.

  • tranid is the transaction issuing the message.

System action

Control is returned to the caller with an error response. For EXEC commands, EIBRESP is set to PGMIDERR and EIBRESP2 is set to indicate the cause of the error.

User response

Ensure the AMODE and RMODE are compatible and the program attribute is specified as resident if the program type is shared.

Module

DFHPGAI

XMEOUT parameters/Message inserts

  1. date
  2. time
  3. applid
  4. terminal
  5. userid
  6. tranid
  7. progname

Destination

CSPL



DFHPG0208.html | Timestamp icon Last updated: Sunday, 4 June 2017