DFHPA1943    applid START=COLD OR START=INITIAL MAY NOT BE SPECIFIED WITH OFFSITE=YES. CICS IS TERMINATED.

Explanation

The system initialization override OFFSITE=YES has been specified but START=COLD or START=INITIAL has also been specified. OFFSITE=YES means that CICS is being restarted in offsite recovery mode, but recovery is not possible on a cold or initial start, so this combination of system initialization parameters is incompatible.

System action

CICS initialization is terminated.

User response

You should specify START=AUTO when restarting CICS in OFFSITE recovery mode.

If you intended to perform a cold or initial start, and specified OFFSITE=YES in error, either change the OFFSITE override to NO, or remove it and allow it to default to NO.

Module

DFHPADM

Destination

Console



DFHPA1943.html | Timestamp icon Last updated: Sunday, 4 June 2017