DFHMQ0311 E date time applid Unable to start alert monitor CKAM. EIBFN=X'eibfn' EIBRESP=eibresp EIBRESP2=eibresp2 EIBRCODE=X'eibrcode'.
Explanation
During the connection process, the CICS-MQ adapter is unable to start the alert monitor CKAM.
System action
The queue manager is connected, but CKAM is not started so the function of the CICS-MQ adapter is restricted.
User response
Without the alert monitor, the CICS-MQ adapter is unable to perform the following functions:
-
It cannot handle a deferred connection
-
It cannot respond to a queue manager failure
-
It cannot perform a warm or immediate shutdown if it needs to wait (that is, the last task carries out shutdown)
It is recommended that you use CKQC to terminate the connection using a forced shutdown of the CICS adapter.
The EIB fields contain information about the cause of the problem. See the Reference: application development manual for an explanation of these values, and take the appropriate action.
Module
XMEOUT parameters/Message inserts
- date
- time
- applid
- X'eibfn'
- eibresp
- eibresp2
- X'eibrcode'
Destination
CMQM, Console and Terminal End User