DFHMC4001I date time applid Error purge delay inoperative, {transid | invalid req | unexpected} error
Explanation
An error return code has been received from the interval control program (ICP) during initiation of the purge delay transaction, CSPQ.
The return code is caused by one of the following.
-
A TRANSID error.
-
An INVALD REQ error.
-
An UNEXPECTED error.
System action
Purge delay does not operate for this execution of CICS. A dump is taken.
User response
-
For a TRANSID error, define transaction CSPQ.
-
For an INVALD REQ, the ICP returned an INVALID REQUEST return code in response to the INITIATE request. Determine why this has occurred and correct the problem.
-
For an UNEXPECTED error, the ICP returned an unrecognized error code in response to the INITIATE request. The error code can be found in the dump at label MCPINERR in program DFHMCP. Determine why this has occurred and correct the problem.
Module
XMEOUT parameters/Message inserts
- date
- time
- applid
- Value chosen from the following options:
1=transid, 2=invalid req, 3=unexpected
Destination
CSMT