DFHLG0776    applid The MVS logger has returned an alert during operation IXGWRITE for log stream lsn. The log stream staging data set has failed. MVS logger codes: X'ret' X'rsn'.

Explanation

The CICS log manager has detected an alert while attempting to access a log stream. The log stream staging data set has failed.

For further guidance, see the z/OS MVS Programming: Assembler Services Reference ABE-HSP.

System action

An exception entry is made in the trace table.

CICS continues normal operation, but the data written to the log stream structure is not being duplexed. Consequently, if the structure (or coupling facility) fails, the data cannot be recovered.

User response

You are recommended to shutdown CICS as soon as possible. You should investigate and fix the failing log stream, without losing the data.

If the failing log stream is the CICS system log and CICS was shutdown immediately, you should emergency restart CICS in order to recover the inflight transactions.

Module

DFHL2HSF

XMEOUT parameters/Message inserts

  1. applid
  2. lsn
  3. X'ret'
  4. X'rsn'

Destination

Console