DFHFC6026 date time applid An error has occurred while notifying VSAM RLS of the completion of CICS processing for a data set quiesce or backup. The SMSVSAM server is not available. Data set dsname
Explanation
CICS has notified VSAM RLS that it has completed its processing for a data set quiesce, or a BWO or non-BWO backup, but the SMSVSAM server address space is not available.
System action
CICS processing continues. The SMSVSAM server address space should attempt to restart automatically.
The data set operation may fail or succeed, depending on whether the SMSVSAM server concerned was coordinating the operation or not.
User response
The SMSVSAM server address space should normally restart itself. If it does not, restart the SMSVSAM server address space manually. Retry the data set operation if it has failed.
If the SMSVSAM server address space fails to restart, a more severe error is indicated. In this case, you will need assistance from IBM. See IBM problem support for guidance on how to proceed.
Module
XMEOUT parameters/Message inserts
- date
- time
- applid
- dsname
Destination
CSFL and Console