DFHFC0162 applid A VSAM data cache has failed.
Explanation
A data cache structure being used by VSAM RLS has failed.
System action
The application request which encountered the error receives an 'IOERR' response.
CICS also issues message DFHFC0158 to display the VSAM diagnostic information for this error. The name of the failing cache can be derived from the information displayed in the following DFHFC0158 message.
While the data cache remains unusable, all data sets bound to this cache are also unusable. Any attempt to read from or write to such a data set cause an IOERR response.
CICS issues messages DFHFC0162 and DFHFC0158 the first time that an I/O request fails because of a cache failure. To prevent flooding the console with messages, CICS does not display these messages again until it is notified that a cache has been recovered. If several caches fail, DFHFC0162 and DFHFC0158 are only displayed for the first cache to fail. However, VSAM issues messages for all failed caches.
User response
Allocate a new data cache and bring it on line to VSAM.
CICS is notified as soon as the new cache is available and is able to take appropriate recovery action.
Module
XMEOUT parameters/Message inserts
- applid
Destination
Console