DFHFC0157 applid tranid termid userid An I/O error has occurred on base data set dsname accessed via file filename component code X'code'.
Explanation
An I/O error has been reported by VSAM after a request to update VSAM file filename.
The name of the base data set associated with the file is dsname although the error may have been encountered elsewhere. This is indicated by the value of the component code X'code'. Its possible values and the corresponding error locations are as follows.
-
X'00' or X'01' - Base cluster.
-
X'02' or X'03' - Alternate index.
-
X'04' or X'05' - Upgrade set.
System action
The application request which encountered the error receives an 'IOERR' response.
CICS also issues message DFHFC0158 to display the VSAM diagnostic information for this error.
User response
Follow standard procedure for I/O errors. No special additional action is required to respond to this particular message although the data set name and component code may help in identifying the problem.
Module
XMEOUT parameters/Message inserts
- applid
- tranid
- termid
- userid
- dsname
- filename
- X'code'
Destination
Console