DFHEX0112 SDUMP request failed - reason X'nn'.
Explanation
An MVS SDUMP request issued from the external CICS interface has failed to complete successfully. The possible reasons, (reason) for the failure are as follows:
- ONLY PARTIAL DUMP
-
The SYS1.DUMP data set to which the dump is written is not large enough to contain all of the dumped storage.
- SDUMP BUSY
-
At the time of the MVS SDUMP request issued by the EXCI, another address space in the same MVS system was in the process of taking an SDUMP. This causes MVS to reject the new request. If a nonzero value is specified for the dump retry parameter in DFHXOPTS table, the EXCI has retried the SDUMP request every five seconds for the specified period. This message is only issued if SDUMP is still busy after the final retry.
- STIMERM FAILED
-
In order to delay for five seconds before retrying SDUMP after an SDUMP BUSY condition, the EXCI issues an MVS STIMERM macro request. MVS has indicated that the STIMERM request has failed.
- NO DATA SET AVAILABLE
-
No SYS1.DUMP data sets were available at the time the SDUMP request was issued.
- REJECTED BY MVS, REASON = X'nn'
-
MVS has rejected the SDUMP request because of user action (for example, specifying DUMP=NO in the MVS IPL) or because of an I/O error or terminating error in the SDUMP routine. X'nn' is the SDUMP reason code.
- NOT AUTHORIZED FOR EXCI
-
SDUMP is not authorized for the external CICS interface.
- INSUFFICIENT STORAGE
-
The EXCI issued an MVS GETMAIN for subpool 253 storage during the processing of the SDUMP request. The GETMAIN has been rejected by MVS.
System action
The EXCI proceeds as if the dump had been successful.
User response
The user response depends on the reasons, (reason), for the failure.
- ONLY PARTIAL DUMP
-
Increase the size of the SYS1.DUMP data sets and cause the SDUMP request to be reissued.
- SDUMP BUSY
-
Cause the SDUMP to be reissued after, if appropriate, increasing the dump retry time in DFHXCOPT.
- STIMERM FAILED
-
Use MVS problem determination methods to fix the STIMERM failure and then cause the SDUMP request to be reissued.
- NO DATA SET AVAILABLE
-
Clear a SYS1.DUMP data set and then cause the SDUMP request to be reissued.
- REJECTED BY MVS, REASON = X'nn'
-
No action is required if the dump is suppressed deliberately. If the dump has failed because of an error in the MVS SDUMP routine, use MVS problem determination methods to fix the error and then cause the SDUMP request to be reissued. See the z/OS MVS Programming: Authorized Assembler Services Reference (Volume 1). for an explanation of the SDUMP reason code X'nn'.
- NOT AUTHORIZED FOR EXCI
-
This reason is unlikely because SDUMP is unconditionally authorized during EXCI initialization, and should be authorized throughout the EXCI run. If you do get this reason, the EXCI AFCB (authorized function control block) has probably been accidentally overwritten.
- INSUFFICIENT STORAGE
-
Ensure sufficient storage is available to MVS for subpool 253 requests.
Module
Destination
Console