DFHEC1013 date time applid The CICS event capture component failed to create the EVENTBINDING resource evbname in BUNDLE bundle because {the LOCALCCSID SIT parameter is not supported | the event binding schema level is not supported | the event binding USERTAG is invalid | the EP adapter name is invalid | of an invalid numeric filter value | the EP adapterset name is invalid | CICSEPSchemaVersion is invalid | CICSEPSchemaRelease is invalid}: error_data.
Explanation
An error has occurred creating event binding evbname in bundle bundle. Possible reasons include:
- LOCALCCSID SIT parameter is not supported
-
Event processing uses the LOCALCCSID system initialization parameter as the default CCSID for code page conversion of character data. It must be a CICS supported single or multibyte EBCDIC CCSID.
- Schema level is not supported
-
The CICSEPSchemaVersion and CICSEPSchemaRelease of the event binding error_data must not be higher than the schema level supported by this release of CICS. The schema level can be found using the INQUIRE EVENTPROCESS command.
- USERTAG is invalid
-
The acceptable 1-8 characters of a userTag are A-Z a-z 0-9 and _. Leading and embedded blank characters are not permitted. The name must not begin with 0-9, _ or the characters xml (in any case).
- EP adapter name is invalid
-
The eventAdapterName in the event binding XML is invalid. The adapter name has the same restrictions as the userTag mentioned previously.
- Invalid numeric filter value
-
The value is invalid for a numeric filter predicate.
- EP adapterset name is invalid
-
The eventAdapterSetName in the event binding XML is invalid. The adapterset name has the same restrictions as the userTag mentioned previously.
- CICSEPSchemaVersion is invalid
-
The specified 1-2 character string must consist of numeric characters only, i.e. 0-9, and be in the range 1-99.
- CICSEPSchemaRelease is invalid
-
The specified 1-2 character string must consist of numeric characters only, i.e. 0-9, and be in the range 0-99.
System action
An exception entry is made in the trace table.
An exception response is returned to the caller of this domain and the event binding create is terminated.
Message DFHME0116, which contains the symptom string for this problem, is produced.
User response
This message is probably caused by an error or inconsistency in the event binding XML. If the event binding was built by the CICS event binding editor, this message might indicate an error in CICS code. Inspect the CICS trace and EC domain message log for any related trace entries or messages. Validate the event binding against the event processing schema for the CICS system into which the bundle is being installed. Correct the event binding, discard the bundle, and reinstall it.
Module
XMEOUT parameters/Message inserts
- date
- time
- applid
- evbname
- bundle
- Value chosen from the following options:
1=the LOCALCCSID SIT parameter is not supported, 2=the event binding schema level is not supported, 3=the event binding USERTAG is invalid, 4=the EP adapter name is invalid, 5=of an invalid numeric filter value, 6=the EP adapterset name is invalid, 7=CICSEPSchemaVersion is invalid, 8=CICSEPSchemaRelease is invalid - error_data
Destination
CECO