DFHDB2016 date time applid The connection of CICS to DB2 {subsystem | group} db2-id failed with reason X'reason-code'.
Explanation
The CICS-DB2 attachment facility startup cannot complete because an error occurred while connecting to DB2 sub-system or group db2-id. The response from DB2 was reason-code.
System action
The CICS-DB2 attachment facility initialization does not complete.
User response
Analyze the DB2 reason code given and any prior messages issued to the attachment error destination or CDB2 TS queues to determine the source of the error. Some possible causes include:
-
incorrect DB2 subsystem or group specified
-
the DB2 subsystem or group was not initialized during MVS IPL processing.
-
Another CICS or IMS region has connected to the DB2 coordinator with the same name as the region issuing this message. For CICS the connection name is the same as the applid.
Module
DFHD2STR, DFHD2CM1
XMEOUT parameters/Message inserts
- date
- time
- applid
- Value chosen from the following options:
1=subsystem, 2=group - db2-id
- X'reason-code'
Destination
CDB2