DFHCA5608 S    date time applid netname tranid Command is terminated. Error occurred while reading a secondary CSD record.

Explanation

An I/O error has occurred on the secondary CSD file.

System action

The SERVICE command is terminated. If commands are being read from a SYSIN data stream by the utility, subsequent commands are checked for syntax only.

User response

Check that the input and output data sets have been correctly defined, and that the DDNAME for the secondary CSD file in the JCL corresponds to the FROMCSD parameter in the SERVICE utility command.

If the problem persists, try to obtain a print out of the CSD, using either IDCAMS or the DFHCSDUP LIST ALL option. The LIST indicates where errors have occurred because they will not print and are therefore easily identifiable.

Module

DFHCAP

XMEOUT parameters/Message inserts

  1. date
  2. time
  3. applid
  4. netname
  5. tranid

Destination

CSMT



DFHCA5608S.html | Timestamp icon Last updated: Sunday, 4 June 2017