DFHCA5117 S    date time applid netname tranid The primary CSD has been defined with an invalid record size. Processing is terminated.

Explanation

The CSD utility cannot initialize the CSD file, because it has been defined to VSAM with an invalid record length.

System action

The CSD file remains uninitialized, and no utility commands are processed.

User response

Delete the CSD file, using VSAM Access Method Services (AMS). In the JCL defining the CSD cluster, change the AMS control statements to specify RECORDSIZE(200 2000). Use this JCL to redefine the CSD file, and use the CSD utility to reinitialize it.

Module

DFHCAP

XMEOUT parameters/Message inserts

  1. date
  2. time
  3. applid
  4. netname
  5. tranid

Destination

CSMT