605: VERIFY_BLOCK_GM_ERROR

During Initialize_User processing, a GETMAIN failed for an EXCI internal control block.

System Action

Initialize_User processing is terminated. The return code from the GETMAIN is returned in the subreason field-1 of the EXCI return area. This error occurs before EXCI dumping services are initialized, Therefore EXCI issues an MVS™ abend (U0409) to force a SYSMDUMP The return code from the MVS GETMAIN request is returned in the return area.

User Response

Locate the GETMAIN return code in the dump, and use this and the rest of the dump to determine why the GETMAIN failed. A possible reason for this is that the region size specified for the job is too small. If this is the case, increase the region size and restart the client application program.



dfhtmc00148.html | Timestamp icon Last updated: Monday, 5 June 2017