Diagnosing APPC autoinstall problems
When diagnosing APPC autoinstall problems, first refer to Diagnosing autoinstall problems. Most of points in that section apply to APPC autoinstall problems except for points that refer to autoinstall models.
Any APPC autoinstall problem should be accompanied by message DFHZC6920 to 23. These messages each have exception trace entries which should trace enough information to allow you to diagnose the problem.
There are three autoinstall instances of DFHZC2411:
- 4 System termination - CSASTIM tested.
- 5 z/OS® Communications Server termination - TCTVVTQS tested.
- 6 ISC=NO specified in the SIT.
There are two additional instances of DFHZC2433:
- 3 Autoinstall disabled - TCTVADEN tested in DFHZBLX.
- 4 Autoinstall temporarily disabled - TCTVADIN tested in DFHZBLX.
There are two additional instances of DFHZC3482:
- 3 No MVS™ storage for DFHZBLX to obtain MVS AWE storage.
- 4 No MVS storage for reporting a failure in a dummy work element.