Active monitor specifications - POLMON

The Active monitor specifications (POLMON) views display information about monitor specifications installed in CICS® systems known to the CICSplex identified as the current context.

Deactivating or discarding a monitor specification

When a monitor specification is installed, the Definition status field is either of the following:
ACTIVE
The specification is installed and active.
PENDING
The specification is installed and ready to become active.
The specification is active during the time period identified in the Activation period field. (When this field is blank, the monitor specification is to be active as long as the CICS system in which it is installed is running.)
To change the status of an installed monitor specification:
  • To deactivate a monitor specification with an ACTIVE status for which a time period is defined:
    • Access the Active monitor specifications tabular view (POLMON object).
    • Click the Record check box beside the monitor specification to be deactivated and click the Deactivate... button. The Deactivate view is displayed.
    • Click Yes to deactivate the selected monitor specification. Otherwise, click No to abandon the process.
    The specification remains installed; its status is changed to PENDING. The next time the end of the associated time period is reached, the specification will become active again.
  • To discard a specification with an ACTIVE or PENDING status and to remove the definition from the CICS system in which it is installed:
    • Access the Active monitor specifications tabular view (POLMON object).
    • Click the Record check box beside the monitor definition to be discarded and click the Discard... button. The Discard view is displayed.
    • Click Yes to discard the selected monitor definition. Otherwise, click No to abandon the process.
Note:
  1. You cannot deactivate or discard a monitor definition created by CICSPlex® SM. These definitions have names that consist of an asterisk (*) followed by seven digits.
  2. Changes that you make to monitor definitions may be overridden by RTA. If RTA needs a definition that you are attempting to deactivate or had previously deactivated, an error message to that effect is issued and your deactivation is overridden.
  3. Deactivating a monitor specification does not remove the data that has been collected and accumulated up to this point in the current monitor interval. The data continues to be displayed in the appropriate monitor views, whether or not the data is being updated. If you know that the data will not be updated by any other active monitor definitions, you can remove it from the view by using the Remove... button.
  4. If there are multiple monitor definitions, the data for discarded definitions continues to be displayed unless and until all of the definitions are discarded.
  5. While deactivating and discarding prevent monitoring of the specific resource occurrence identified in the monitor definition, other active monitor definitions may continue to cause information about that resource occurrence to be gathered. To illustrate, suppose the following monitor definitions are active:
    • EYUMOD01, which identifies all file names beginning with PAY
    • EYUMOD02, which identifies all file names beginning with P
    Discarding EYUMOD01 has no affect on monitoring since EYUMOD02 includes all file names beginning with P. However, discarding EYUMOD02 means that file names beginning with PAY continue to be monitored.
  6. Issuing a DSC or DEA command for a MONDEF for the MTRAN class will result in no more history collection for those transactions.


eyuabh9.html | Timestamp icon Last updated: Sunday, 4 June 2017